Ultrasonic Flow Meter KTM600 RUS ®
Technical metering of natural gas, oil-dissolved gas and other gas media and mixtures
Benefits:
- Operating pressure (excess) to 55 МPа at turned solid design;
- Stainless steel, Monel* or Hastelloy** versions;
- Metering of hydrogen H2 and pure gases;
- Metering of fume-laden and humid gases, hydrates and gases with high content of mechanical impurities;
- Metering of cryogenic media to -194°C;
- Turned solid versions to DN1400;
- Measurement error to ± 0.5-1.5 %;
- Calculation of gas mass flow rate without a density meter by “Hydrocarbon” method;
- Sensors replacement under operating pressure;
- Service life – 15 years.
* is a trademark owned by Special Metals Corporation
** is a trademark owned by Haynes International
METROLOGY AND TECHNICAL CHARACTERISTICS
| Parameter name | Parameter value | Remark |
| Inside diameter, mm |
from 50 tо 1400 |
|
| Lengths of straight sections |
5 х DN 10 х DN 20 х DN |
If an orifice box is available
After leadaway in 1 plane
After leadaway in 2 planes |
| Medium temperature, 0C |
-60 .. +180 |
Extended range: -194…+280 |
| Medium excess pressure, МPа |
from 0 to 45 |
Extended range: tо 55 |
| Untrasound sensors operation frequency, kHz |
80; 135; 200; 350 |
With deviation ±5% |
| Number of measurement channels |
2Р (parallel arrangement) 2Х (criss-cross arrangement) 4Р (parallel arrangement) 8X (criss-cross arrangement) |
|
| Limits of gas volume flow rate measurement relative error under operating conditions, % |
±0,7 – 1 ±1,5 – 3 ±0,5 – 1 ±0,5 – 1 |
2Р 2Х 4Р 8X |
| Calibration interval, years |
4 |
|
| Number of information processing units (IPUs) |
1,2 * |
* — depending on a version |
| Ambient temperature, °С |
-40 ..+60 |
Extended range: -65…+65 with a thermal cover |
| IP degree of protection according to GOST 14254 (IEC 60529)
-Information processing unit with transmitter-receiver units; -Remote module |
IP66/IP67 IP54 |
|
| Explosion-proof marking |
1 Ex db eb ia [ia Ga] T6…T4 IIC Gb X |
|
| Outputs and interfaces |
— frequency (time period signal TPS)/pulse output; — analog configurable output, current loop with support of HART; — RS-485 with support of Modbus RTU and Modbus ASCII; — Ethernet with support of Modbus TCP; — analog input for temperature and pressure sensors, current loop with support of HART |
|
| Power voltage, V |
12…30 |
|
| Input power, W |
Not more than 6 |
|
| Mean time to failure term, h |
88000 |
|
| Service life, years |
15 |
STANDARD SIZES AND FLOW RANGES
| Nominal meter diameter | Volume flow rate in operating conditions m3/h | Maximum gas velocity, m/s | ||
|---|---|---|---|---|
| DN | Qmin | Qт | Qmax | Vmax |
| 50 | 4 | 13 | 400 | 65 |
| 80 | 8 | 32 | 1000 | 65 |
| 100 | 13 | 50 | 1600 | 60 |
| 150 | 20 | 80 | 3000 | 50 |
| 200 | 32 | 130 | 4500 | 45 |
| 250 | 50 | 240 | 7000 | 40 |
| 300 | 65 | 375 | 8000 | 33 |
| 350 | 80 | 375 | 10000 | 33 |
| 400 | 120 | 600 | 14000 | 33 |
| 450 | 130 | 650 | 17000 | 33 |
| 500 | 200 | 975 | 20000 | 33 |
| 600 | 320 | 1500 | 32000 | 33 |
| 700 | 400 | 2000 | 40000 | 30 |
| 750 | 400 | 2000 | 45000 | 30 |
| 800 | 400 | 2400 | 50000 | 30 |
| 900 | 650 | 3750 | 66000 | 30 |
| 1000 | 650 | 5000 | 80000 | 30 |
| 1050 | 1300 | 6000 | 85000 | 30 |
| 1100 | 1400 | 6500 | 90000 | 28 |
| 1200 | 1600 | 7000 | 100000 | 27 |
| 1300 | 2000 | 7300 | 110000 | 26 |
| 1400 | 2300 | 8600 | 130000 | 25 |