(function(w,d,s,l,i){w[l]=w[l]||[];w[l].push({'gtm.start': new Date().getTime(),event:'gtm.js'});var f=d.getElementsByTagName(s)[0], j=d.createElement(s),dl=l!='dataLayer'?'&l='+l:'';j.async=true;j.src= 'https://www.googletagmanager.com/gtm.js?id='+i+dl;f.parentNode.insertBefore(j,f); })(window,document,'script','dataLayer','GTM-WNPJVVF');

We use cookies to omprove your experience on the site. Please read our Privacy Тerms to find more.

I accept I refuse Learn more

Ultrasonic Flow Meter KTM600 RUS ®

Benefits:

  • Operating pressure (excess) to 55 МPа at turned solid design;
  • Stainless steel, Monel* or Hastelloy** versions;
  • Metering of hydrogen H2 and pure gases;
  • Metering of fume-laden and humid gases, hydrates and gases with high content of mechanical impurities;
  • Metering of cryogenic media to -194°C;
  • Turned solid versions to DN1400;
  • Measurement error to ± 0.5-1.5 %;
  • Calculation of gas mass flow rate without a density meter by “Hydrocarbon” method;
  • Sensors replacement under operating pressure;
  • Service life – 15 years.

* is a trademark owned by Special Metals Corporation

** is a trademark owned by Haynes International

METROLOGY AND TECHNICAL CHARACTERISTICS  

Parameter nameParameter valueRemark
Inside diameter, mm

from 50 tо 1400

Lengths of straight sections

5 х DN

10 х DN

20 х DN

If an orifice box is available

 

After leadaway in 1 plane

 

After leadaway in 2 planes

Medium temperature, 0C

-60 .. +180

Extended range: -194…+280

Medium excess pressure, МPа

from 0 to 45

Extended range: tо 55

Untrasound sensors operation frequency, kHz

80; 135; 200; 350

With deviation ±5%

Number of measurement channels

2Р (parallel arrangement)

2Х (criss-cross arrangement)

4Р (parallel arrangement)

8X (criss-cross arrangement)

Limits of gas volume flow rate measurement relative error under operating conditions, %

±0,7 – 1

±1,5 – 3

±0,5 – 1

±0,5 – 1

8X

Calibration interval, years

4

Number of information processing units (IPUs)

1,2 *

* — depending on a version

Ambient temperature, °С

-40 ..+60

Extended range:

-65…+65 with a thermal cover

IP degree of protection according to GOST 14254 (IEC 60529)

-Information processing unit with transmitter-receiver units;

-Remote module

 

 

IP66/IP67

IP54

Explosion-proof marking

1 Ex db eb ia [ia Ga] T6…T4 IIC Gb X

Outputs and interfaces

— frequency (time period signal TPS)/pulse output;

— analog configurable output, current loop with support of HART;

— RS-485 with support of Modbus RTU and Modbus ASCII;

— Ethernet with support of Modbus TCP;

— analog input for temperature and pressure sensors, current loop with support of HART

Power voltage, V

12…30

Input power, W

Not more than 6

Mean time to failure term, h

88000

Service life, years

15

STANDARD SIZES AND FLOW RANGES

Nominal meter diameterVolume flow rate in operating conditions m3/hMaximum gas velocity, m/s
DNQminQтQmaxVmax
5041340065
80832100065
1001350160060
1502080300050
20032130450045
25050240700040
30065375800033
350803751000033
4001206001400033
4501306501700033
5002009752000033
60032015003200033
70040020004000030
75040020004500030
80040024005000030
90065037506600030
100065050008000030
1050130060008500030
1100140065009000028
12001600700010000027
13002000730011000026
14002300860013000025