We use cookies to omprove your experience on the site. Please read our Privacy Тerms to find more.

I accept Learn more

Ultrasonic Flow Meter KTM600 RUS ®

Technical metering of natural gas, oil-dissolved gas and other gas media and mixtures

Benefits:

  • Operating pressure (excess) to 55 МPа at turned solid design;
  • Stainless steel, Monel* or Hastelloy** versions;
  • Metering of hydrogen H2 and pure gases;
  • Metering of fume-laden and humid gases, hydrates and gases with high content of mechanical impurities;
  • Metering of cryogenic media to -194°C;
  • Turned solid versions to DN1400;
  • Measurement error to ± 0.5-1.5 %;
  • Calculation of gas mass flow rate without a density meter by “Hydrocarbon” method;
  • Sensors replacement under operating pressure;
  • Service life – 15 years.

* is a trademark owned by Special Metals Corporation

** is a trademark owned by Haynes International

 

METROLOGY AND TECHNICAL CHARACTERISTICS  

Parameter name Parameter value Remark
Inside diameter, mm

from 50 tо 1400

Lengths of straight sections

5 х DN

10 х DN

20 х DN

If an orifice box is available

 

After leadaway in 1 plane

 

After leadaway in 2 planes

Medium temperature, 0C

-60 .. +180

Extended range: -194…+280

Medium excess pressure, МPа

from 0 to 45

Extended range: tо 55

Untrasound sensors operation frequency, kHz

80; 135; 200; 350

With deviation ±5%

Number of measurement channels

2Р (parallel arrangement)

2Х (criss-cross arrangement)

4Р (parallel arrangement)

8X (criss-cross arrangement)

Limits of gas volume flow rate measurement relative error under operating conditions, %

±0,7 – 1

±1,5 – 3

±0,5 – 1

±0,5 – 1

8X

Calibration interval, years

4

Number of information processing units (IPUs)

1,2 *

* – depending on a version

Ambient temperature, °С

-40 ..+60

Extended range:

-65…+65 with a thermal cover

IP degree of protection according to GOST 14254 (IEC 60529)

-Information processing unit with transmitter-receiver units;

-Remote module

 

 

IP66/IP67

IP54

Explosion-proof marking

1 Ex db eb ia [ia Ga] T6…T4 IIC Gb X

Outputs and interfaces

– frequency (time period signal TPS)/pulse output;

– analog configurable output, current loop with support of HART;

– RS-485 with support of Modbus RTU and Modbus ASCII;

– Ethernet with support of Modbus TCP;

– analog input for temperature and pressure sensors, current loop with support of HART

Power voltage, V

12…30

Input power, W

Not more than 6

Mean time to failure term, h

88000

Service life, years

15

STANDARD SIZES AND FLOW RANGES

Nominal meter diameter Volume flow rate in operating conditions m3/h Maximum gas velocity, m/s
DN Qmin Qт Qmax Vmax
50 4 13 400 65
80 8 32 1000 65
100 13 50 1600 60
150 20 80 3000 50
200 32 130 4500 45
250 50 240 7000 40
300 65 375 8000 33
350 80 375 10000 33
400 120 600 14000 33
450 130 650 17000 33
500 200 975 20000 33
600 320 1500 32000 33
700 400 2000 40000 30
750 400 2000 45000 30
800 400 2400 50000 30
900 650 3750 66000 30
1000 650 5000 80000 30
1050 1300 6000 85000 30
1100 1400 6500 90000 28
1200 1600 7000 100000 27
1300 2000 7300 110000 26
1400 2300 8600 130000 25