Ultrasonic Flow Meter KTM600 RUS ®
Technical metering of natural gas, oil-dissolved gas and other gas media and mixtures
Benefits:
- Operating pressure (excess) to 55 МPа at turned solid design;
- Stainless steel, Monel* or Hastelloy** versions;
- Metering of hydrogen H2 and pure gases;
- Metering of fume-laden and humid gases, hydrates and gases with high content of mechanical impurities;
- Metering of cryogenic media to -194°C;
- Turned solid versions to DN1400;
- Measurement error to ± 0.5-1.5 %;
- Calculation of gas mass flow rate without a density meter by “Hydrocarbon” method;
- Sensors replacement under operating pressure;
- Service life – 15 years.
* is a trademark owned by Special Metals Corporation
** is a trademark owned by Haynes International
METROLOGY AND TECHNICAL CHARACTERISTICS
Parameter name | Parameter value | Remark |
Inside diameter, mm | from 50 tо 1400 | |
Lengths of straight sections | 5 х DN 10 х DN 20 х DN | If an orifice box is available
After leadaway in 1 plane
After leadaway in 2 planes |
Medium temperature, 0C | -60 .. +180 | Extended range: -194…+280 |
Medium excess pressure, МPа | from 0 to 45 | Extended range: tо 55 |
Untrasound sensors operation frequency, kHz | 80; 135; 200; 350 | With deviation ±5% |
Number of measurement channels | 2Р (parallel arrangement) 2Х (criss-cross arrangement) 4Р (parallel arrangement) 8X (criss-cross arrangement) | |
Limits of gas volume flow rate measurement relative error under operating conditions, % | ±0,7 – 1 ±1,5 – 3 ±0,5 – 1 ±0,5 – 1 | 2Р 2Х 4Р 8X |
Calibration interval, years | 4 | |
Number of information processing units (IPUs) | 1,2 * | * — depending on a version |
Ambient temperature, °С | -40 ..+60 | Extended range: -65…+65 with a thermal cover |
IP degree of protection according to GOST 14254 (IEC 60529) -Information processing unit with transmitter-receiver units; -Remote module |
IP66/IP67 IP54 | |
Explosion-proof marking | 1 Ex db eb ia [ia Ga] T6…T4 IIC Gb X | |
Outputs and interfaces | — frequency (time period signal TPS)/pulse output; — analog configurable output, current loop with support of HART; — RS-485 with support of Modbus RTU and Modbus ASCII; — Ethernet with support of Modbus TCP; — analog input for temperature and pressure sensors, current loop with support of HART | |
Power voltage, V | 12…30 | |
Input power, W | Not more than 6 | |
Mean time to failure term, h | 88000 | |
Service life, years | 15 |
STANDARD SIZES AND FLOW RANGES
Nominal meter diameter | Volume flow rate in operating conditions m3/h | Maximum gas velocity, m/s | ||
---|---|---|---|---|
DN | Qmin | Qт | Qmax | Vmax |
50 | 4 | 13 | 400 | 65 |
80 | 8 | 32 | 1000 | 65 |
100 | 13 | 50 | 1600 | 60 |
150 | 20 | 80 | 3000 | 50 |
200 | 32 | 130 | 4500 | 45 |
250 | 50 | 240 | 7000 | 40 |
300 | 65 | 375 | 8000 | 33 |
350 | 80 | 375 | 10000 | 33 |
400 | 120 | 600 | 14000 | 33 |
450 | 130 | 650 | 17000 | 33 |
500 | 200 | 975 | 20000 | 33 |
600 | 320 | 1500 | 32000 | 33 |
700 | 400 | 2000 | 40000 | 30 |
750 | 400 | 2000 | 45000 | 30 |
800 | 400 | 2400 | 50000 | 30 |
900 | 650 | 3750 | 66000 | 30 |
1000 | 650 | 5000 | 80000 | 30 |
1050 | 1300 | 6000 | 85000 | 30 |
1100 | 1400 | 6500 | 90000 | 28 |
1200 | 1600 | 7000 | 100000 | 27 |
1300 | 2000 | 7300 | 110000 | 26 |
1400 | 2300 | 8600 | 130000 | 25 |