We use cookies to omprove your experience on the site. Please read our Privacy Тerms to find more.

I accept I refuse Learn more

Ultrasonic Flow Meter KTM700 RUS ®

Benefits:

  • Operating pressure (excess) to 45 МPа at turned solid design;
  • Turned solid versions to DN1400;
  • Metering of hydrogen H2 and pure gases;
  • Metering of fume-laden and humid gases, gases with high content of mechanical impurities (UGS);
  • Metering of corrosive gases (made from designated stainless steels: Monel*, Hastelloy** and other at customer’s request);
  • Compensation of housing geometric dimesions change by temperature and pressure;
  • Measurement error to ± 0.5%;
  • Simulation calibration period ±0.7%;
  • Calculation of gas mass flow rate without a density meter by “Hydrocarbon” method;
  • Separate calculation for the Customer and the Consumer with two independent meters in one housing (Quadro version);
  • CMC;
  • Possibility of sensors replacement under operating pressure;
  • Service life – 20 years.

* is a trademark owned by Special Metals Corporation

** is a trademark owned by Haynes International

 

METROLOGY AND TECHNICAL CHARACTERISTICS  

Parameter name Parameter value Remark
Inside diameter, mm

from 50 tо 1400

Lengths of straight sections

5 х DN

10 х DN

20 х DN

If an orifice box is available

 

After leadaway in 1 plane

 

After leadaway in 2 planes

Medium temperature, 0C

-70 .. +180

Extended range: -194…+280

Medium excess pressure, МPа

from 0 to 28

Extended range: tо 45

Untrasound sensors operation frequency, kHz

80; 135; 200; 350

With deviation ±5%

Number of measurement channels
1P(parallel arrangement)



2P(parallel arrangement)



4P(parallel arrangement)



8P(parallel arrangement)



2+2 (quad version) 2Q


4+4 (quad version) 4Q
Limits of gas volume flow rate measurement relative error under operating conditions, %
 

Qmin<Q<Qt

 

±0.7*

 

Qt<Q<Qmax

 

±0.5

Calibration interval, years

4

Number of information processing units (IPUs)

1,2 *

* — depending on a version

Ambient temperature, °С

-40 ..+60

Extended range:

-65…+65 with a thermal cover

IP degree of protection according to GOST 14254 (IEC 60529)

-Information processing unit with transmitter-receiver units;

-Remote module

 

 

IP66/IP67

IP54

Explosion-proof marking

1 Ex db eb ia [ia Ga] IIC T6…T2  Gb X

Outputs and interfaces

— frequency (time period signal TPS)/pulse output;

— analog configurable output, current loop with support of HART;

— RS-485 with support of Modbus RTU and Modbus ASCII;

— Ethernet with support of Modbus TCP;

— analog input for temperature and pressure sensors, current loop with support of HART

Power voltage, V

12…30

Input power, W

Not more than 6

Mean time to failure term, h

88000

Service life, years

20

Standard sizes and flow ranges

Meter diameter Gas flow rate in operating conditions m3/h Gas velocity, m/s
Qmin Qт Qmax Vmax

DN50

1

13

400

65
DN80 5 40 1000 61
DN100 8 65 1600 63
DN150 16 100 3000 52
DN200 20 160 4500 44
DN250 25 240 7000 44
DN300 35 310 8000 39
DN350 45 420 10000 36
DN400 60 550 14000 38
DN450 100 700 17000 37
DN500 130 850 20000 35
DN550 150 1000 24000 35
DN600 180 1200 32000 39
DN650 240 1400 35000 36
DN700 280 1700 40000 36
DN750 320 1900 45000 35
DN800 360 2200 50000 34
DN850 400 2500 55000 33
DN900 450 2800 66000 36
DN950 500 3100 70000 34
DN1000 550 3400 80000 35
DN1050 600 3800 85000 34
DN1100 650 4100 90000 32
DN1150 700 4500 95000 34
DN1200 750 4800 100000 30
DN1300 900 5600 110000 28
DN1400 1000 6500 130000 27

 

Notes:

Qmin – minimal flow rate;

Qmax — maximal flow rate;

Qt — limit flow rate;

Vmax — maximal gas velocity;

Vt — limit gas velocity= 1,5 m/s